Features

• 12.1′ color TFT LCD screen supports display max. 9 waveforms

• Personated voice reminding alarm; Visual On-display and integrated alarm light

• Real time S-T segment analysis, pace detection and arrhythmia analysis

• Drug calculation and titration table

• Extended advance function: 2IBP, IOC, EtCO2, Multi-Gas/ O2

• Suitable for monitoring adult, pediatric and neonatal patient.

• Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG.

• Supporting storage of 720 hours patient data, 1000 NIBP records and 500 alarm event

• External lead-acid battery

• Multi-language: Chinese, English, Spanish, Portuguese, Russian, French, German, Czech,

• Denish, Dutch, Finland, Italian, Polish, Turkish


YSF8’s Standard Configuration

• Anti-glare screen, Rechargeable lead-acid battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature


YSF8’s Optional Configuration

• 2IBP, Nellcor SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream/ Micro-stream CO2), Multi-Gas/ O2, Pitch Tone

• VGA, Thermal printer (50 mm)

• Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2 probe

• Central Monitoring System

Technical Specification
Physical Specifications Dimension 340mm(W)*280mm(H)*130mm(D)
Weightstandard configuration: 4 kg
Power requirementsAC 90-300V, 50/60HZ, 60W
Power90VA
Temperature0-40℃
Humidity0-93% non-condensing
SafetyMeet the requirements of IEC60601 series
Patient rangeAdult, neonate and pediatric patients
Performance Specification Display 12.1’ (800 x 600 pixel) color TFT LCD screen, support external VGA (option). rolling and refreshing waveform display
Display modeStandard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG.
InterfaceParameter cable interface
AC power input socket
Network interface
External VGA interface for connection of alternate display
Battery1 internal rechargeable lead-acid battery, 2.0Ah 12V
Alarm indicatorVisual on-display and integrated alarm light
Audible alarm and personated voice reminding alarm
Data storage720 hours monitoring data
10000NIBP records storage
500 alarm event.
PrinterBuilt-in 50mm thermal printer (option),
3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s
print width:50mm
Net workingSupport connection to central monitoring station through LAN (TCP/IP) or wireless connection
ECG Leads type 3/5-lead: I, II, III, aVR, aVL, aVF, V
Sweep speed12.5mm/s, 25mm/s,50mm/s
Gain selection×0.25, ×0.5, ×1, ×2
ECG waveform3 channels
Operation modeDiagnostic, monitor, surgery
Heart rate range15 -350bpm
Accuracy1bpm or ±1% whichever is great
Alarm rangeAudible and visual alarm, adjustable
ST/ arrhythmiaReal time S-T segment detection, pace detection and arrhythmia analysis
ProtectionAgainst electrosurgical interference and defibrillation
Respiration (RESP) Method Thoracic impedance
Operation modeAuto/manual
Measurement rangeAdult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarmYes
AlarmYes, audible and visual alarm, alarm events recallable
NIBP Method Automatic oscillometric
Operation modeManual/Automatic/STAT
Auto measure timeAdjustable
Measurement unitmmHg / kPa selectable
Test interval1-480 minutes
Measurement rangeAdult: 0-300 mmHg;
Child: 0-240 mmHg;
Infant: 0-150 mmHg
Over-pressure protectionDouble safety protection
Accuracy of blood pressure measurementThe mean error shall be less than±5mmHg
the standard deviation shall be less than 8mmHG
Resolution1 mmHg
SpO2 Measurement range 0%-100%
Resolution1%
Accuracy ±2% (70-100%, adult/pediatric, non-motion)
±3% (70-100%, neonate, non-motion)
±3% (70-100%, adult/pediatric/neonate, motion)
0-69% unspecified
Alarm range1-100%
Pulse range:0-350bpm
Accuracy:±3bpm(non-motion)
±5bpm (motion)
Temperature (TEMP) TEMP range 0-50℃
Resolution0.1 ℃
Accuracy±0.1℃ (excluding the sensor)
ChannelDual-channel. provide T1; T2; △T
IBP Measurement range -50-360mmHg
Channel2 channels
Pressure transducerSensitive: 5u V/V mmHg
Impedance range: 300-3000 Ω
Pressure namesART, PA, CVP, RAP, LAP, ICP, P1, P2
Alarm range-10-300 mmHg
PR from IBP Range & Accuracy:
25-200bpm ±1bpm or ±1bpm which is greater
201-350bpm ±2%
Resolution:
1bpm
Depth of Anesthesia (BIS) EEG sensitivity +/- 475μV
Noise< 2uVp-p (1-150 Hz)
CMRR> 100 dB
Input impedance> 50mohm
Sample rate1024 samples/s, 16 bits

Scroll to Top